A Solid Foundation for Reliable, Safe and Practical Safety Compliance Testing
GW Instek is launching to the market a series of safety tester (hi-pot tester/hipot tester) with high durability and multiple user-protection design. The GPT-9800 supports the major test items among all the needed for the compliance of the safety standards such as IEC, EN, UL, CSA, GB, JIS and other safety regulations.
A total of 4 safety testers in the GPT-9800 Series, namely GPT-9804, GPT-9803, GPT-9802 and GPT-9801, are available for various applications. The GPT-9804 is a 4-in-1 model capable of performing AC withstanding, DC withstanding, insulation resistance and ground bond tests. The GPT-9803 is a 3-in-1 model capable of performing AC withstanding, DC withstanding as well as insulation resistance tests. The GPT-9802 is capable of performing both AC and DC withstanding tests, whereas the GPT-9801 is able to perform AC withstanding test. The series of safety tester is built upon a high-efficiency PWM amplifier platform with AC 200VA maximum output capacity to impede the influence from the voltage fluctuation of the input AC source. This ensures a stable voltage supply for all the tests of the GPT-9800 Series.
Targeting user’s protections, the GPT-9800 series uses a combination of hardware and software controls to improve safety: A self-check is performed to make sure all the functions and operations are under normal condition each time when the tester is turned on; the Zero Crossing Turn-On design imposes the output voltage to always begin at the zero crossing of a sine wave to avoid the impact of surge voltage output; and the output voltage is automatically cut off (within 150μs) when abnormal output voltages have been detected or when the upper or lower current limits have been reached during testing. To protect operator from hazardous injury, the GPT-9800 Series automatically discharges the DUT after test (within 200ms) each time to eliminate excessive voltage that remains on the DUT. To further ensure safety, the interlock connector can also be used as double protections to prevent inadvertent operation.
The GPT-9800 Series, equipped with a simple & clear panel layout, a high resolution dot matrix LCD display, and color LED indicators, allows operators to interpret measurement results easily and quickly. All major test functions, including AC withstanding (AC 5kV/40mA), DC withstanding (DC 6kV/10mA), insulation resistance (DC 50V ~ 1000V) and ground bond (AC 30A max.) tests, are performed under a high-stability voltage output with high-resolution measurement results. Further more, the test duration, ramp up time and upper/lower limits of the output voltage are fully-adjustable to accommodate a wide variety of safety tests with accurate measurement results.
Other functions and features of the GPT-9800 include: open circuit detection for ground bond testing to get correct measurement result with confidence; 100 sets of memory to save panel settings, which can be recalled for single test individually or for automatic tests in sequence; a remote output on-off terminal in the front panel and a signal I/O port in the rear panel provided as the means for remote start/stop control of the safety tester; RS-232C, USB and GPIB (optional) interfaces available for PC remote control and test result logging.
The specifications apply when the GPT-9800 is powered on for at least 30 minutes under +15°C~+35°C.
Model \ Func. | GPT-9804 | GPT-9803 | GPT-9802 | GPT-9801 |
AC WITHSTANDING | v | v | v | v |
DC WITHSTANDING | v | v | v | × |
INSULATION RESISITANCE | v | v | × | × |
GROUND BOND | v | × | × | × |
AC WITHSTANDING | ||
Output-Voltage Range | 0.050kV~ 5.000kV ac | |
Output-Voltage Resolution | 2V/step | |
Output-Voltage Accuracy | ± (1% of setting +5V) [no load] | |
Maximum Rated Load | 200 VA (5kV/40mA) | |
Maximum Rated Current | 40mA (0.5kV < V ≦ 5kV) 10mA (0.1kV ≦ V≦ 0.5kV) |
|
Output-Voltage Waveform | Sine wave | |
Output-Voltage Frequency | 50 Hz / 60 Hz selectable | |
Voltage regulation | ± (1% of reading +5V) [full load →no load] | |
Voltmeter Accuracy | ± (1% of reading+ 5V) | |
Current Measurement Range | 0.001mA~040.0mA | |
Current Best Resolution | 0.001mA / 0.01mA / 0.1mA | |
AC Current Measurement Accuracy | ±(1.5% of reading +30 counts) when HISET < 1.11mA ±(1.5% of reading +3 counts) when HISET ≧ 1.11mA |
|
Window Comparator Method | Yes | |
ARC Detect | Yes | |
RAMP (Ramp-Up Time) | 0.1~999.9s | |
TIMER (Test Time)* | OFF**, 0.5s~999.9s | |
GND | ON/OFF | |
DC WITHSTANDING | ||
Output-Voltage Range | 0.050kV~ 6.000kV dc | |
Output-Voltage Resolution | 2V/step | |
Output-Voltage Accuracy | ± (1% of setting +5V) [no load] | |
Maximum Rated Load | 50W (5kV/10mA) | |
Maximum Rated Current | 10mA (0.5kV < V ≦ 6kV) 2mA (0.05kV ≦ V≦ 0.5kV) |
|
Voltage regulation | ± (1% of reading +5V) [[full load → no load] | |
Voltmeter Accuracy | ± (1% of reading+ 5V) | |
Current Measurement Range | 0.001mA~010.0mA | |
Current Best Resolution | 0.001mA / 0.01mA / 0.1mA | |
DC Current Measurement Accuracy | ±(1.5% of reading +30 counts) when HISET < 1.11mA ±(1.5% of reading +3 counts) when HISET ≧ 1.11mA |
|
Window Comparator Method | Yes | |
ARC Detect | Yes | |
RAMP (Ramp-Up Time) | 0.1~999.9s | |
TIMER (Test Time)* | OFF**, 0.5s~999.9s | |
GND | ON/OFF | |
INSULATION RESISITANCE | ||
Output-Voltage | 50V~1000V dc | |
Output-Voltage Resolution | 50V/step | |
Output-Voltage Accuracy | ± (1% of setting +5V) [no load] | |
Resistance Measurement Range | 1 MΩ~ 9500 MΩ | |
Test voltage | Measurable Range | Accuracy |
50V≦V≦450V | 1 MΩ~ 50 MΩ 51 MΩ~ 2000 MΩ |
±(5% of reading +1 count) ±(10% of reading +1 count) |
500V≦V≦1000V | 1 MΩ~ 500 MΩ 501 MΩ~ 9500 MΩ |
±(5% of reading +1 count) ±(10% of reading +1 count) |
Window Comparator Method | Yes | |
Output Impedance | 600 kΩ | |
RAMP (Ramp-Up Time) | 0.1~999.9s | |
TIMER (Test Time)* | 1s~999.9s | |
GND | OFF (fixed) | |
GROUND BOND | ||
Output-Current Range | 03.00A~30.00A ac | |
Output-Current Resolution | 0.01A | |
Output-Current Accuracy | 3A≦I≦8A : ± (1% of setting +0.2A) 8A<I≦30A : ± (1% of setting +0.05A) |
|
Test-Voltage | 6Vac max. (open circuit) | |
Test-Voltage Frequency | 50 Hz / 60 Hz selectable | |
Resistance Measurement Range | 10mΩ~650.0mΩ | |
Resistance Measurement Resolution | 0.1mΩ | |
Resistance Measurement Accuracy | ± (1% of reading +2mΩ) | |
Window Comparator Method | Yes | |
TIMER (Test Time)* | 0.5s~999.9s | |
GND | OFF (fixed) | |
Test Method | Four Terminal | |
MEMORY | ||
Single Step Memory | MANU : 100 blocks | |
Automatic Testing Memory | AUTO : 100 blocks, menu per auto : 16 | |
INTERFACE | ||
RS232 | Standard | |
USB (Device) | Standard | |
GPIB | Option | |
Remote Terminal (Front) | Standard | |
SIGNAL IO | Standard | |
GENERAL | ||
Display | 240 x 64 dot matrix LED back light LCD | |
Power Source | AC100V/120V/220V/230V ±10%, 50/60Hz | |
Power Consumption | 500VA max. | |
Dimensions & Weight | 330(W) x 148(H) x 452(D) mm (Max.), approx.19kg(Max) |
|
* TIMER Accuracy: ± (100ppm + 20ms) | ||
**The “TIMER OFF” can only be performed when the tester is in the special MANU mode |
Included Accessories
Power cord x1, Interlock key x1,
Remote terminal Cable GHT-119 x1,
Test lead GHT-114 x1 for GPT-9803/9802/9801
Test lead GHT-114 x1, GTL-215 x 1 for GPT-9804
Option
GPT-9KG1 GPIB card
GPT-9KR1 RS-232 card
GSB-01 Multiplex Scanner Box (8CH H.V)
GSB-02 Multiplex Scanner Box (6CH H.V./2CH G.B.)
Optional Accessories
GHT-113 High Voltage Test Pistol, approx. 1000mm
GHT-117 High Voltage Adapter Box
GHT-117 (EU) High Voltage Adapter Box
GHT-118 High Voltage / Ground Bond Adapter Box
GHT-118 (EU) High Voltage / Ground Bond Adapter Box
GHT-121 High Voltage Test Lead, approx. 3000mm
GHT-205 High Voltage Test Probe, approx. 1100mm
GTL-232 RS232C Cable, 9-pin Female to 9-pin, null Modem for Computer, Approx. 2000mm
GTL-247 USB Cable, A-A type, approx. 1800mm
GTL-248 GPIB Cable, approx. 2000mm
GRA-417 RACK Mount Kit (19”, 4U)