EMI Solution - GSP-9330, GKT-008, GLN-5040A, GIT-5060
EMI Solution
EMI Solution
Features
  • Simplify the complicated EMC measurement and debugging
  • Including Conduction EMI Testing, Radiation EMI Testing
  • GSP-9330 Spectrum analyzer with EMI Mode
  • GKT-008 EMI Probe Set for pretest
  • GLN-5040A LISN for conduction testing
  • GIT-5060 AC isolated transformer (Discontinued)
  • GPL-5010 Transient Limiter

 

*GIT-5060 has been discontinued

 

 


Simplify the complicated EMC measurement and debugging!

The continuous integration and complication of consumer electronics have produced numerous electromagnetic radiation sources. EMC tests can ensure various electronics products’ safety and effectiveness. In order to reduce the development cost and shorten development time, more and more companies are now focusing on EMC planning at the preliminary design phase. In addition to sending products to the lab, they are also looking for or try to establish an EMC solution which is cost effective and test effective diagnosis method.

GW Instek introduces the latest and comprehensive EMC pre-compliance testing solution to meet customers’ requirements of EMC conduction and radiation testing during product development and verification stages. The EMC pre-compliance testing mode is ideal for electronics product development. With this solution, users can resolve problems at the earliest phase to avoid reconfiguration once the product development was finalized. Reducing product development cycles and verification laboratory fees are conducive to expediting the process of product verification and launch time.

For different test categories, GW Instek provides different test packages,

Radiation EMI testing package

- Spectrum Analyzer: GSP-9330
- EMI Near Field Probe Set: GKT-008
- DC Block: ADB-008
- Transient Limiter: GPL-5010

Conduction and radiation EMI testing package

- Spectrum Analyzer: GSP-9330
- EMI Near Field Probe Set: GKT-008
- DC Block: ADB-008
- Two-Line V-Network(LISN): GLN-5040A
- Transient Limiter: GPL-5010
- Isolated Transformer: GIT-5060 (Discontinued)

Conduction EMI testing package

- Spectrum Analyzer: GSP-9330
- Two-Line V-Network(LISN): GLN-5040A
- Transient Limiter: GPL-5010
- Isolated Transformer: GIT-5060  (Discontinued)

Radiation EMS testing package

- Spectrum Analyzer: GSP-9330 + Tracking Generator
- EMI Near Field Probe Set: GKT-008

01 gw_product_detail_bar.png GSP-9330 Spectrum Analyzer

EMC pretest mode collocates with near field probe or antenna to carry out conduction and radiation electromagnetic interference (EMI) test. Additionally, near field probe and GSP-9330 tracking generator can be used to output 0dBm RF signals to test electromagnetic susceptibility (EMS) for electronics products.

EMC pretest mode collocates with near field probe or antenna to carry out conduction and radiation electromagnetic interference (EMI) test. Additionally, near field probe and GSP-9330 tracking generator can be used to output 0dBm RF signals to test electromagnetic susceptibility (EMS) for electronics products.

SpectrumShot – EMI dedicated function, Users can use the external software SpectrumShot for EMI test report management and assessment. Users can select the required CISPR EMI regulation for conduction and radiation measurement.

02 gw_product_detail_bar.png GKT-008 EMI Near Field Probe Set

GKT-008 EMI Near Field Probe Set comprises four probes, including PR-01, PR-02, ANT-04, and ANT-05.

The antenna factors of these four probes are built in the EMC Pretest function of the GSP-9330 spectrum analyzer.

ANT-04 and ANT-05 are EMI magnetic field probes, which can maximally sustain 50Vdc. ANT-04 and ANT-05 magnetic field probes will collocate with ADB-008 DC block to avoid damaging spectrum analyzer and the RF input terminal of DUT receiver.

PR-01 is an AC voltage probe, which can maximally sustain CAT II, 300VAC. PR-01 AC voltage probe will collocate with GPL-5010 transient limiter and BNC (M) to SMA (F) adapter to avoid damaging spectrum analyzer and the RF input terminal of DUT receiver.

PR-02 is an EMI electric field probe, which can maximally sustain CAT I 50V DC. PR-02 electric field probe will collocate with ADB-008 DC block to avoid damaging spectrum analyzer and the RF input terminal of DUT receiver.

03 gw_product_detail_bar.png GLN-5040A Two-Line V-Network(LISN)

GLN-5040A Two-Line V-Network(LISN) that met CISPR16-1-2:2006 standard is a required product for EMI conduction testing.

Built-in transient limiter and fixed 10dB attenuator to effectively protect spectrum analyzer.Built-in 150 KHz high pass filter switch to prevent spectrum analyzer or DUT receiver overload caused by low-frequency high amplitude signals.
Provide artificial hand function to simulate human hand impedance on handheld device (such as electric drill) measurement.

50 Ω output impedance and BNC output adaptor can collocate with spectrum analyzer.

Provide stable impedance for DUT and reference ground under testing frequency range.

Isolate the interfering signals produced by city electric power from the testing circuit to provide pure DC and AC power to DUT.
Couple DUT interfering voltage with spectrum analyzer.

04 gw_product_detail_bar.png GIT-5060 isolated transformer (Discontinued)

Before connecting LISN, users can connect a GIT-5060 isolated transformer as the following diagram to balance grounding L and N phase current by ELCB function in order to realize a safe grounding.

Under the necessary circumstances, GIT-5060 can be used if isolated transformer is required. It can maximally sustain consecutive current of 4A and its maximum capacity is 900VA that satisfies most testing requirements.

05 gw_product_detail_bar.png GPL-5010 Transient Limiter

Why do you need a transient limiter?

Large transient signals will enter spectrum analyzer if the system experiences unexpected power outage or sudden errors from power supply terminal. For an unstable system, a transient limiter can disrupt large signals and prevents them from going into equipment to cause damage.

 

GSP-9330 spectrum analyzer

Power Cord, Certificate of Calibration, CD-ROM (with User Manual, Programming Manual, SpectrumShot Software, SpectrumShot Quick Start Guide & IVI Driver)

GKT-008 EMI Probe Set

User Manual

GPL-5010 Transient Limiter

User Manual,Warranty Card,Test Report,N(M) to BNC(F)

GLN-5040A Two-Line V-Network(LISN)

User Manual,Adaptor BNC(F) to N-type(M),Cable BNC(M) to BNC(M),German Standard Power Adaptor,Warranty Card,Test Report

GIT-5060 Isolated transformer  (Discontinued) Power Cord, User Manual, Warranty Card

 

Options
GSP-9330 spectrum analyzer Opt.01 Tracking Generator

Opt.02 Battery Pack

Opt.03 GPIB Interface

ADB-008 DC Block 50ohm,SMA(male)~SMA(female),0.1MHz-8GHz

 

Optional Accessories
GSC-009 portable backpack
GRA-415 rack panel
Free Download SpectrumShot Software EMI pretest and remote control software for GSP-9330 (available on GW Instek website)
IVI Driver for GSP-9330 supports LabVIEW/LabWindows/CVI (available on NI website)

 

Radiation EMI testing package
Radiation EMI testing package Where to buy
Conduction EMI testing package
Conduction EMI testing package Where to buy
Conduction and radiation EMI testing package
Conduction and radiation EMI testing package Where to buy
Radiation EMS testing package
Radiation EMS testing package Where to buy
User Manual
The user manual of GSP-9330
2024-04-17
User Manual versionA.,EN 6.88 MB DOWNLOAD
User Manual
The GIT-5060 user manual
2018-01-04
User Manual version1.,EN 252.0 KB DOWNLOAD
User Manual
The GLN-5040A user manual
2018-01-04
User Manual version1.,EN 704.0 KB DOWNLOAD
User Manual
The GPL-5010 user manual.
2018-01-04
User Manual version1.,EN 354.8 KB DOWNLOAD
User Manual
The GKT-008 user manual.
2020-02-11
User Manual version.,EN 1.5 MB DOWNLOAD
Application Note
The EMI probe, GKT-008 near field probe set, application note with GSP-9330
2018-01-04
Application Note version1.,EN 2.2 MB DOWNLOAD